Growatt Single Phase Inverter SPH 4000TL BL-UP 4kW PV Inverter Hybrid Inverter
Datasheet | SPH3000TL BL-UP | SPH3600TL BL-UP | SPH4000TL BL-UP | SPH4600TL BL-UP | SPH5000TL BL-UP | SPH6000TL BL-UP |
Input data(PV) | ||||||
Max. recommended PV power (for module STC) | 6000W | 7200W | 8000W | 9200W | 10500W | 11200W |
Max. DC voltage | 550V | |||||
Start voltage | 120V | |||||
MPP voltage range | 120-550V/360V | |||||
No. of MPP trackers | 2 | |||||
No. of PV strings per MPP tracker | 1 | |||||
Max. input current per MPP tracker | 13.5A | |||||
Max short-circuit current per MPP tracker | 16.5A | |||||
Output data(AC) | ||||||
AC nominal power | 3000W | 3680W | 4000W | 4600W | 5000W | 6000W |
Max. AC apparent power | 3000VA | 3680VA | 4000VA | 4600VA | 5000VA | 6000VA |
Nominal AC voltage (range) | 230V/(180Vac-270Vac) | |||||
AC grid frequency (range) | 50Hz/60Hz (45Hz-55Hz/55Hz-65Hz) | |||||
Max. output current | 16A | 16A | 22A | 22A | 27A | 27A |
Adjustable power factor | 0.8leading...0.8lagging | |||||
THDI | <3% | |||||
AC grid connection type | Single phase | |||||
Battery data (DC) | ||||||
Battery voltage range | 42-59V | |||||
Max charging and discharging current | 66A | 75A | 85A | 85A | 85A | 85A |
Continuous charging and discharging power | 3000W | 3680W | 4000W | 4000W | 4000W | 4000W |
Type of battery | Lithium /Lead-acid | |||||
Backup power(AC) | ||||||
Max. AC output power | 3000W | 3680W | 4000W | 4000W | 4000W | 4000W |
Max. output current | 17.4A | |||||
Nominal AC output voltage | 230Vac | |||||
Nominal AC output frequency | 50/60HZ | |||||
THDv | <3% | |||||
Switch time | <10ms | |||||
Efficiency | ||||||
MAX. efficiency | 97.20% | 97.20% | 97.30% | 97.40% | 97.50% | 97.60% |
European efficiency | 97% | 97% | 97.10% | 97.10% | 97.20% | 97.20% |
MPPT efficiency | >99.5% | |||||
Protection devices | ||||||
DC switch | Yes | |||||
DC reverse polarity protection | Yes | |||||
AC/DC surge protection | Yes | |||||
Battery reverse protection | Yes | |||||
AC short-circuit protection | Yes | |||||
Ground fault monitoring | Yes | |||||
Grid monitoring | Yes | |||||
Anti-islanding protection | Yes | |||||
Residual-current monitoring unit | Yes | |||||
Insulation resistance monitoring | Yes | |||||
General data | ||||||
Dimensions (W/H/D) | 458/565/188mm | |||||
Weight | 31kg | |||||
Operating temperature range | -25°C ... +60°C | |||||
Nighttime power consumption | < 10 W | |||||
Topology | Transformerless | |||||
Cooling | Natural | |||||
Protection degree | IP65 | |||||
Relative humidity | 0-100% | |||||
Altitude | 2000m | |||||
PV DC Connection | H4/MC4(Optional) | |||||
Battery DC Connection | OT Terminal | |||||
AC connection | Connector | |||||
Display | LCD+LED | |||||
Interfaces:RS485/CAN/USB | Yes | |||||
Monitor: RF/WIFI/GPRS | Optional | |||||
Warranty: 5 years/10 years | Yes/Optional | |||||
Specification | ||||||
SPH 3000-6000TL BL-UP | on&off grid single phase inverter | |||||
CE, IEC62109, G98/G99, VDE0126-1-1, AS4777, CEI 0-21, VDE-AR-N4105, UTE C 15-712, EN50549, IEC 61727, IEC 62116, IEC 62040, C10/11, NRS 097-2-1 |