Hot-selling products Growatt MIC 3000TL-X 3000W 3KW 1 MPPT Single phase on grid PV solar Inverter
Datasheet
|
MIC 750TL-X
|
MIC 1000TL-X
|
MIC 1500TL-X
|
MIC 2000TL-X
|
MIC 2500TL-X
|
MIC 3000TL-X
|
MIC 3300TL-X
|
|||||||
Input data (DC)
|
|
|
|
|
|
|
|
|||||||
Max. recommended PV power(for module STC)
|
1050W
|
1400W
|
2100W
|
2800W
|
3500W
|
4200W
|
4290W
|
|||||||
Max. DC voltage
|
500V
|
500V
|
500V
|
500V
|
550V
|
550V
|
550V
|
|||||||
Start voltage
|
50V
|
50V
|
50V
|
50V
|
80V
|
80V
|
80V
|
|||||||
Nominal voltage
|
120V
|
180V
|
250V
|
360V
|
360V
|
360V
|
360V
|
|||||||
MPP voltage range
|
50V-500V
|
50V-500V
|
50V-500V
|
50V-500V
|
65V-550V
|
65V-550V
|
65V-550V
|
|||||||
No. of MPP trackers
|
1
|
|
|
|
|
|
|
|||||||
No. of PV strings per MPP tracker
|
1
|
|
|
|
|
|
|
|||||||
Max. input current per MPP tracker
|
13A
|
|
|
|
|
|
|
|||||||
Max. short-circuit current per MPP tracker
|
16A
|
|
|
|
|
|
|
|||||||
Output data (AC)
|
|
|
|
|
|
|
|
|||||||
AC nominal power
|
750W
|
1000W
|
1500W
|
2000W
|
2500W
|
3000W
|
3300W
|
|||||||
Max. AC apparent power
|
750VA
|
1000VA
|
1500VA
|
2000VA
|
2500VA
|
3000VA
|
3300VA
|
|||||||
Nominal AC voltage(range*)
|
230V (180-280V)
|
|
|
|
|
|
|
|||||||
AC grid frequency(range*)
|
50/60 Hz (45-55Hz/55-65 Hz)
|
|
|
|
|
|
|
|||||||
Max. output current
|
3.6A
|
4.8A
|
7.1A
|
9.5A
|
11.9A
|
14.3A
|
14.3A
|
|||||||
Adjustable power factor
|
0.8leading…0.8lagging
|
|
|
|
|
|
|
|||||||
THDi
|
<3%
|
|
|
|
|
|
|
|||||||
AC grid connection type
|
Single phase
|
|
|
|
|
|
|
|||||||
Efficiency
|
|
|
|
|
|
|
|
|||||||
Max.efficiency
|
97.4%
|
97.4%
|
97.4%
|
97.4%
|
97.6%
|
97.6%
|
97.6%
|
|||||||
European efficiency
|
96.5%
|
96.5%
|
97.0%
|
97.0%
|
97.0%
|
97.1%
|
97.1%
|
|||||||
MPPT efficiency
|
99.9%
|
|
|
|
|
|
|
|||||||
Protection devices
|
|
|
|
|
|
|
|
|||||||
DC reverse polarity protection
|
Yes
|
|
|
|
|
|
|
|||||||
DC switch
|
Yes
|
|
|
|
|
|
|
|||||||
AC/DC surge protection
|
Type III / Type III
|
|
|
|
|
|
|
|||||||
Insulation resistance monitoring
|
Yes
|
|
|
|
|
|
|
|||||||
AC short-circuit protection
|
Yes
|
|
|
|
|
|
|
|||||||
Ground fault monitoring
|
Yes
|
|
|
|
|
|
|
|||||||
Grid monitoring
|
Yes
|
|
|
|
|
|
|
|||||||
Anti-islanding protection
|
Yes
|
|
|
|
|
|
|
|||||||
Residual-current monitoring unit
|
Yes
|
|
|
|
|
|
|
|||||||
AFCI protection
|
Optional
|
|
|
|
|
|
|
|||||||
General data
|
|
|
|
|
|
|
|
|||||||
Dimensions (W / H / D)
|
274/254/138mm
|
|
|
|
|
|
|
|||||||
Weight
|
6kg
|
6kg
|
6kg
|
6kg
|
6.2kg
|
6.2kg
|
6.2kg
|
|||||||
Operating temperature range
|
–25°C ... +60°C
|
|
|
|
|
|
|
|||||||
Nighttime power consumption
|
< 0.5W
|
|
|
|
|
|
|
|||||||
Topology
|
Transformerless
|
|
|
|
|
|
|
|||||||
Cooling
|
Natural convection
|
|
|
|
|
|
|
|||||||
Protection degree
|
IP65
|
|
|
|
|
|
|
|||||||
Relative humidity
|
0-100%
|
|
|
|
|
|
|
|||||||
Altitude
|
4000m
|
|
|
|
|
|
|
|||||||
DC connection
|
H4/MC4(Optional)
|
|
|
|
|
|
|
|||||||
AC connection
|
Connector
|
|
|
|
|
|
|
|||||||
Display
|
|
|
|
|
|
|
|
|||||||
Interfaces: RS485 / USB/Wi-Fi/ GPRS/ RF/LAN
|
Yes/Yes/Optional/Optional/Optional /Optional
|
|
|
|
|
|
|
|||||||
Warranty: 5 years / 10 years
|
Yes /Optional
|
|
|
|
|
|
|
|||||||
CE,AS4777, AS/NZS 3100, CEI 0-21, VDE-AR-N 4105, VDE 0126-1-1, UTE C 15-712-1, EN50549, IEC 60068, IEC 61683, IEC 62116, IEC61727,
INMETRO, G98, C10/C11, UNE217001, UNE206007, PO12.2 |
|
|
|
|
|
|
|